Automatic Transmission Schedule
Go to Interface Configuration>Automatic Transmission Schedule.
This utility allows the external system to receive data in pre-definable, regular intervals. The AR EXPORT, BLOCK, INVENTORY, PROFILE REQUEST and PROFILE DAILY STATS data modules are currently supported. At the time the next transmission kicks in, all data for the selected data module between the last transmission and this transmission is sent with this utility. This does not require Opera business events, but it does require an OXI 2-way license code. When a message is sent it is identified as RTAV. Users can set up as many schedules as will meet the business requirements of the site.
Example for blocks: The automatic transmission interval is set to 2 hours and for 30 days in advance. Once the interval waiting time has elapsed and the next transmission is due, OXI will check all block header and block details for changes between the last transmission time and now, and will send all blocks that have changed and that have start dates between today and 30 days in advance, as full overlays to the external system.
Example for Profile Daily Stats: Use the Profile Daily Stats data module to schedule an upload of daily profile statistics to an external system. It is recommended that the user selects "Daily" and "2.00 AM" for the frequency and time to run.
Interfaces that currently utilize this functionality: PEGASUS, SPIRIT and DELPHI.
Example: Below a view of a configured Automatic Transmission Schedule screen.
New. Allows system user to create multiple Transmission schedules based on business requirements.
Edit. Allows the user the ability to modify existing schedule. Interval, Range and Active flag can be updated only.
Delete. Delete an existing transmission schedule.
Refresh. Will refresh the last send date.
Example: Below a view of two records (Inventory and Block) after selecting the Edit button.
Interface. Interface ID for which the automatic transmission schedule is set.
Property. Opera property code configured for this interface ID.
Module. The data module for which the automatic transmission schedule is set. Currently OXI supports the following modules: AR EXPORT, BLOCK, INVENTORY, PROFILE REQUEST and PROFILE DAILY STATS.
Frequency. Choice of Daily, Weekly, Monthly, Yearly and Interval settings for transmissions. Works with the setting, Interval to Run.
Interval to Run. Interval in seconds, minutes and or days between the automatic transmissions. Works with Frequency choice.
Range. Number of days in advance for which automatic transmission shall occur. Sample: If the range is set to 30 days, OXI will send data with start dates from today until 30 days in advance. Automatic Transmission has a message limitation. If the range of days exceeds 30 days, for example 60 days, then the transmission will be 2 RTAV messages of 30 days each. If the range of days is 90, then the transmission will be 3 RTAV messages of 30 days each, etc.
Last Send. Date when last automatic transmission occurred.
Active. Check this flag to activate the automatic transmission. If this box is not flagged the transmission will NOT take place.
ATS screen selection if done for Blocks:
Delta Setting to modify how the Block Header and Grid information will be sent.